RGBP-ResCom® Global Building Products, founded in Queensland, Australia in 2009. RGBP and our associates have created a strong history of proven performance in the construction industry. Our foundation, built over the past 16 years, is based on lifecycle performance related to outdoor environmental sustainability and healthy, non-toxic indoor product solutions.

ResCom® Boards are an engineered and evolved manufacturing formulation that has registered patents in the United States, Australia, Canada, China, New Zealand, and the United Kingdom, as well as several individual and joint system patents that utilize the ResCom® core material products.

  • ResCom® Flat Sheet Fiber Reinforced Magnesia Cement Board has a flame spread index of 10 or less and a smoke-developed index of 5   or less when tested in accordance with ASTM E84. ResCom® Boards   are classified as noncombustible building materials in accordance   with ASTM E136.
  • ResCom® Board product is a lightweight and integrated insulating, cladding, and finishing system for new construction and remodeling   of residential and commercial projects.

The following technical information & test results are the Exclusive Property & Ownership of RGBP Global Group of Companies www.rescombp.com. All results are that of ResCom® (CMC) ISO 8336 certified, patented & manufactured products by ResCom® Building Products. Test results are not transferable to ANY, THIRD PARTY company or product.
If in doubt, contact: rescombp@rescombp.com

RESCOM® CMC ISO:8336 COMPLIANCE TEST REGISTER

Physical Properties Testing Standard Performance Condition
Reaction to fire: 10mm W&C Lining AS ISO 9239.1-2003 Part 1 0/0/0/0 HF-30(kW/m2)
Reaction to fire: 20mm SF AS ISO 9239.1-2003 Part 1 0/0/0/0 HF-30(kW/m2)
Flame Spread & Combustibility AS/NZS; 1530.1: 2014 Class A As per test standards
Flame Spread & Combustibility AS/NZS 3837:1998 Class A As per test standards
Flame Spread & Combustibility ASTM E84 Class A As per test standards
Flame Spread & Combustibility ASTM E276B-11 Class A As per test standards
Flame Spread & Combustibility BS 476: Part 4 Class One As per test standards
Flame Spread & Combustibility BS 476: Part 5 Class One As per test standards
Flame Spread & Combustibility BS 476: Part 6 Class One As per test standards
Flame Spread & Combustibility BS 476: Part 7 Class One As per test standards
Flame Spread & Combustibility BS 476: Part 11 Class One As per test standards
Flame Spread & Combustibility ISO 5660-1:2002 Class A1 & Afl As per test standards
Flame Spread & Combustibility EN ISO 1182-210 Class A1 & Afl As per test standards
Determination to heat combustion EN ISO 1716-2010 Class A1 & Afl As per test standards
Non Combustibility ISO 13501-1:2007+A1:20029 Class A1 As per test standards
Non Combustibility ISO 13501-1:2007+A1:20029 Class Afl As per test standards
FRL Systems Performance BS 476: Part 21: 1987 102/102/71 As per test standards
FRL Systems Performance BS 476: Part 22 >30min to <240min As per test standards
FRL Systems Performance ASTM E119 >30min to <240min As per test standards
FRL Systems Performance AS/NZS 1530: Part 4: 2014 >30min to <240min As per test standards
FRL Systems Performance AS/NZS:5113 Pass As per test standards
Thermal Resistance m2.K/W 0.027 & 0.045 ASTM C518-10 As per test standards
Thermal Conductivity W/mk 0.44 ASTM C518-10 As per test standards
Calorific Value UNE-EN ISO1716 & 1182:2011 0.1092 to 0.2554 As per test standards
Water Impermeability Category A EN 12467:2012 Pass As per test standards
Vapour Permeability Category D EN 12467:2012 Sec 5.4.6 & 7.3.4 u=80 As per test standards
Freeze-Thaw Category A EN 12467:2012 Sec 5.5.2 & 7.4.1 Pass As per test standards
Heat Rain Category A EN 12467:2012 Sec 5.5.3 & 7.4.2 Pass As per test standards
Soak-Dry Category A EN 12467:2012 Sec 5.5.5 & 7.3.6 Pass As per test standards
Swelling & Thickness EN 317:1993 <0.2% Wet
TVOC, Formaldehyde ISO 16000-3, 6,9 & 11: 2006 & 2011 Zero As per test standards
Dimensional conformance ASTM C1185-08 (2012) Pass As per test standards
Density in kg/m3 ASTM C1185-08 (2012) 1000 As per test standards
Water tightness ASTM C1185-08 (2012) Pass As per test standards
Water absorption ASTM C1185-08 (2012) <13.2% As per test standards
EQ Moisture content ASTM C1185-08 (2012) <5% As per test standards
“Moisture movement 30-90% relative humidity *” ASTM C1185-08 (2012) 0.064 As per test standards
“Humidified deflection [mm] 32c,40%RH, 48hrs *” ASTM C1185-08 (2012) 2.18 As per test standards
Average Bending Strength FL ASTM C1185-08 (2012) >14Mpa Wet
Average Bending Strength Wall EN 12467:2012 Sec 5.4.4 & 7.3.2 >12Mpa Wet
Transverse Load-Roof: 10, 12, 16mm ASTM E72-22 Section 12 & 20 Pass Test load 4.45kN
Concentrated load-Roof 10, 12, 16mm ASTM E72-22 Section 13 & 21 Pass Test load 4.45kN
Transverse Load-Roof: 20mm SF ASTM E72-22 Section 12 & 20 Pass Test load 4.45kN
Concentrated load-Roof: 20mm SF ASTM E72-22 Section 13 & 21 Pass Test load 4.45kN

TRACE DOCUMENT #6112023